Fig. 3

Limit of detection of PCR-LFD strips in detecting M. bovis DNA. (A) Results by PCR-LFD (with a detection limit of 89 fg/µL). (B) Results by PCR (with a detection limit of 890 fg/µL). (C) Results by real-time qPCR (with a detection limit of 89 fg/µL)